BGG Cable Manufacturers
SA (Pty) Ltd.
WalroFlex
 
WalroFlex
 
Make Enquiry





           

FLRY-J (-40°C / +105°C)
CONDUCTOR CONSTRUCTION INSULATED CONDUCTOR

Conductor:

Annealed Electrolytic Copper Cu-ETP according to DIN EN13602
DIN 72551, part 6, Type B and ISO 6722

Insulation:

PVC (Polyvinyl Chloride - Lead Free)
Plasticide PVC with properties according to DIN 72551 and
ISO 6722 Class B

Packaging:

Refer General Information

Ordering example:

FLRYB - 0125 - YLWH
Type Size Color
Cross Section DIN 72551 (A) 1.25mm² Yellow White
Material type: PVC
Continuous temperature: 105°C (3000h)
Intermittent temperature: 120°C (48h)
Cold resistance: -40°C
Oil resistant: Yes
Fuel resistant: Yes
Abrasion resistance: As per ISO 6722/LV112
Flame resistance: As per ISO 6722/LV112
Insulation wall thickness: Thin wall
Nominal Cross- Section mm² Number of individual wires Diameter of individual wires mm Bunch Diameter maximum mm Resistance max @ 20 C maximum mÙ/m Insulation wall thickness minimum mm External diameter minimum External diameter maximum Weight approximately kg/1000m (Cu/PVC)
0.85 18 0.25 1.28 21.00 0.24 1.80 2.00 10.50
1.25 25 0.26 1.52 14.80 0.24 2.05 2.25 14.00
2.00 28 0.30 1.97 9.50 0.28 2.50 2.70 22.00
3.00 42 0.30 2.40 6.10 0.32 3.00 3.30 33.00
5.00 70 0.30 3.10 3.70 0.32 3.70 4.00 52.00